CJXVX - DESFLURANE IN ARGON

  • MSDS: CJXVX
  • Manufacturer: SCOTT SPECIALTY GASES INC
  • Product Name: DESFLURANE IN ARGON
  • National Stock Number: 6830-00N092083
Product Identification

Product ID:DESFLURANE IN ARGON
MSDS Date:10/21/1993
FSC:6830
NIIN:00N092083
Status Code:A
MSDS Number: CJXVX

Responsible Party
SCOTT SPECIALTY GASES, INC
6141 EASTON ROAD
PLUMSTEADVILLE, PA 18949
US

Emergency Phone: 800-233-4334

Info Phone: 215-766-8861

Cage: 3Y341

Contractor
SCOTT MEDICAL PRODUCTS,DIV OF SCOTT SPECIALTY
PLUMSTEADVILLE, PA 18949 US

Telephone: 215-766-8861

Cage: 3Y341

Ingredients

DESFLURANE

CAS: 57041-67-5

OSHA PEL N/K

ACGIH TLV: N/K


ARGON

CAS: 7440-37-1

RTECS: CF2300000

Fraction By Weight: BALANCE

OSHA PEL N/K

ACGIH TLV: SIMPLE ASPHYXIANT

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: DESFLURANE IS AN ANESTHETIC AND
MAY CAUSE IRRITATION AND REDNESS TO EYES. MAY CAUSE DRYNESS,
IRRITATION TO SKIN. MAY CAUSE IRRITATION OF THE MOUTH AND THROAT.
OVEREXPOSURE CAN LEAD TO HEADACHES , DIZZINESS/DROWSINESS,
UNCONSCIOUSNESS AND DEATH. MIXTURE ACTS AS A SIMPLE ASPHYXIANT BY
DISPLACING AIR NECESSARY FOR LIFE. SYMPTOMS INCLUDE RAPID
RESPIRATION, MUSCULAR INCOORDINATION, FATIGUE, NAUSE A AND
VOMITING, AND UNCONSCIOUSNESS. CHRONIC: NONE KNOWN.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:INHALATION: IMMEDIATELY REMOVE VICTIM TO FRESH AIR. IF
BREATHING HAS STOPPED, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS
DIFFICULT, GIVE OXYGEN. CONTACT A PHYSICIAN. EYES: FLUSH WITH
POTABLE WATER F OR AT LEAST 15 MINUTES. SEE MD . SKIN: FLUSH WITH
COPIOUS AMOUNTS OF WATER. SEE MD . INGESTION: CALL MD IMMEDIATELY .

Fire Fighting

Flash Point Method:CC
Flash Point:>93.3C, 200.F
(DESFLURANE)
Extinguishing Media:USE WHAT IS APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH APPROVED SELF-CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE EQUIPMENT . USE WATER SPRAY TO COOL
FIRE-EXPOSED CYLINDERS.
Unusual Fire/Explosion Hazard:DESFLURANE EMITS TOXIC FUMES UNDER FIRE
CONDITIONS. CONTAINER EXPLOSION MAY OCCUR UNDER FIRE CONDITIONS.

Accidental Release

Spill Release Procedures:EVACUATE AND VENTILATE AREA. REMOVE LEAKING
CYLINDER TO EXHAUST HOOD OR SAFE OUTDOORS AREA IF THIS CAN BE DONE
SAFELY.

Handling

Handling and Storage Precautions:STORE IN WELL-VENTILATED AREAS ONLY.
KEEP VALVE PROTECTION CAP ON CYLINDERS WHEN NOT IN USE AND SECURE
CYLINDER WHEN USING TO PROTECT FROM FALLING. USE SUITABLE HAND
TRUCK TO MOVE CYLINDERS.
Other Precautions:PROTECT CONTAINERS FROM PHYSICAL DAMAGE. DO NOT
DEFACE CYLINDERS OR LABELS. CYLINDER SHOULD BE REFILLED BY
QUALIFIED PRODUCERS OF COMPRESSED GASES. SHIPMENT OF A COMPRESSED
GAS CYLINDER WHICH HAS NOT BEEN FILLED BY THE OWNER OR WITH HIS
WRITTEN CONSENT IS A VIOLATION OF FEDERAL LAW (49 CFR).

Exposure Controls

Respiratory Protection:USE A NIOSH APPROVED SELF-CONTAINED BREATHING
APPARATUS IN CASE OF EMERGENCY OR NON-ROUTINE USE AS PRODUCT IS A
MILD ANESTHETIC.
Ventilation:PROVIDE ADEQUATE GENERAL AND LOCAL EXHAUST VENTILATION.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYEWASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA . WEAR SAFETY SHOES.
Supplemental Safety and Health
CHEMICAL FORMULA: CF*3CFHOCF*2H. CHEMICAL FAMILY: HALOGENATED ETHER
MIXTURE. PHYSICAL/CHEMICAL PROPERTIES: VAPOR DENSITY (AIR=1): 1.55
(MIXTURE).

Chemical Properties

Boiling Pt:=22.8C, 73.F
B.P. Text:(DESFLURANE)
Vapor Pres:669 MM HG @ 20C
Vapor Density:SUP DAT
Solubility in Water:NEGLIGIBLE @ 20C
Appearance and Odor:CLEAR, COLORLESS, WITH A MILD ETHEREAL ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH PEROXIDES.
Hazardous Decomposition Products:HYDROGEN FLUORIDE.

Disposal

Waste Disposal Methods:RETURN CYLINDERS TO SUPPLIER FOR PROPER DISPOSAL
WITH ANY VALVE OUTLET PLUGS OR CAPS SECURED AND VALVE PROTECTION
CAP IN PLACE. DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS (FP N).

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Regulatory

SARA Title III Information:AROCLOR 1260 SUBJECT TO THE REPORTING
REQUIREMENTS OF SARA TITLE III, SECTION 313.
Federal Regulatory Information:THIS MATERIAL IS NOT LISTED ON THE TSCA
(TOXIC SUBSTANCES CONTROL ACT) INVENTORY. THIS MATERIAL IS INTENDED
FOR R&D USE ONLY AND MAY NOT BE USED FOR DRUG, HOUSEHOLD, OR OTHER
PURPOSES. IT IS SUBJECT T O TSCA REGULATIONS ACT CFR 40 PART 720.36
WHICH DEAL WITH THE EXEMPTION OF CHEMICALS USED IN RESEARCH AND
DEVELOPMENT FROM PMN (PREMANUFACTURE NOTIFICATION) REQUIREMENTS. IN
ADDITION, THE BURDEN OF SA FE USE OF THE MATERIAL RESTS WITH YOU
AND, THEREFORE, IT SHOULD BE HANDLED ONLY BY QUALIFIED PERSONS
TRAINED IN LABORATORY PROCEDURES AND GOOD SAFETY PRACTICES.